Tuckahoe School Addition
2004 American Council of Engineering Companies of New York The Gold Award
22,500 sq. ft. on two floors
Partially buried lower floor with Library and Classrooms, upper floor with multi-purpose Cafetorium, Science room and additional Classrooms. |
Total envelope losses under 20 BTUH/sq.ft. hydronic radiant floors, water-source heat-pumps for cooling, heat-pipes for ventilation heat recovery. Operable Andersen windows. Linoleum finish flooring throughout |